1. NHMIC2-5 | 5" Marquise II, IC Air-Tight New Construction Housing |Nora Lighting
NHMIC2-5 | 5
NHMIC2-5 | 5' Marquise II, IC Air-Tight New Construction Housing |Nora Lighting

NHMIC2-5 | 5" Marquise II, IC Air-Tight New Construction Housing |Nora Lighting

MD-NL-NHMIC2-5
Your Price: $91.08
Retail Price:$127.51
You Save:$36.43(29%)
Free Shipping

Add to cart to see final price

Nora Lighting 5" Marquise II, IC Air-Tight New Construction Housing

Dedicated new construction housing for installation in NonIC or insulated ceilings, must specify. Air-tight construction provides energy savings by reducing the flow of air through the ceiling.

CONSTRUCTION
Plaster Frame: 0.040 steel frame with integral bar hanger brackets. Brackets can accommodate longer 27ï¾” accessory flat bar hangers. Brackets run along all sides of frame to allow bar hangers to be run parallel or perpendicular to junction box.

Housing: 0.040 aluminum one-piece can. Adjustable ceiling thickness from 3/8ï¾” to 7/8ï¾”.

Air Flow Restriction: Housing has factory installed gaskets to restrict airflow from room into ceiling plenum to <2CFM (cubic feet per minute) in accordance with ASTM283 Air-Tight requirements.

Bar Hangers: Two 13-3/4ヤ to 24-1/2ヤ adjustable bar hangers with captive nails are included on frame. Bar hangers are parallel to junction box, but can be repositioned 90ᄎ perpendicular to junction box if desired. モLヤ Shaped bar hanger foot to align to bottom of construction joist. A T-Bar notch allow for easy installation in a suspended ceiling.

Junction Box: Prewired 25 cubic inch 0.064ï¾” thick galvanized steel, with seven 1/2ï¾” knockouts, four Romex® pryouts, and snap on covers. All leads are #18AWG wire, the ground wire is connected to the bottom, and quick connectors are supplied on all leads. Through branch circuit wiring, (4-in, 4-out).

CLEARANCE
Non-IC: Non-Insulated housings require a minimum clearance of 3ï¾” from thermal insulation and 1/2ï¾” from adjacent building components.
IC: Insulated ceiling housings are direct contact rated; no minimum clearance is required.

Electrical
Input Voltage: 120V or 277V
Lumens / Wattage:
NHMIC2-509: 900lm / 15W
Operating Temp.: 0ï¾°C to 45ï¾°C ambient temperature
Dimming:
LE3: 120V Input; Triac/ELV/0-10V dimming
LE6: 120-277V Input; 0-10V dimming

Emergency LED Driver
EM: Emergency Pack w/ Remote Test Switch

Labels and listings
ï¾· cULus Listed for Damp Location w/ Feed Through
ï¾· cULus Wet Listed (Only with designated trims)
ï¾· Meets or exceeds ASTM-283 Air-Tight Requirements

Item Code
NHMIC2-5